Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	21
Date	08/12/14
Start Time	09:54:26
Diameter Midpoint
 10.9	161.608
 11.3	347.099
 11.8	562.703
 12.2	599.03
 12.6	990.269
 13.1	1831.22
 13.6	2033.25
 14.1	3849.08
 14.6	5808.31
 15.1	6994.82
 15.7	11061.8
 16.3	13778.3
 16.8	18290.4
 17.5	24282.9
 18.1	32055.9
 18.8	40219
 19.5	52756.1
 20.2	66285.4
 20.9	76233.7
 21.7	91708.4
 22.5	110069
 23.3	131937
 24.1	158572
 25.0	185585
 25.9	216766
 26.9	255212
 27.9	288550
 28.9	328964
 30.0	372227
 31.1	423116
 32.2	470893
 33.4	512385
 34.6	567938
 35.9	623787
 37.2	682043
 38.5	737530
 40.0	790089
 41.4	834215
 42.9	867464
 44.5	883942
 46.1	934639
 47.8	939948
 49.6	933076
 51.4	922988
 53.3	943927
 55.2	924986
 57.3	922312
 59.4	918592
 61.5	898712
 63.8	873992
 66.1	843825
 68.5	828357
 71.0	795117
 73.7	749548
 76.4	716885
 79.1	668564
 82.0	629034
 85.1	565864
 88.2	510764
 91.4	444159
 94.7	377273
 98.2	315004
101.8	256026
105.5	204172
109.4	160398
113.4	125523
117.6	96196.8
121.9	73448.3
126.3	56344.2
131.0	42830.7
135.8	32534.6
140.7	25215.9
145.9	19789.2
151.2	15992.1
156.8	13693.7
162.5	11759.2
168.5	10410.9
174.7	9681.06
181.1	8683.95
187.7	7861.94
194.6	7005.77
201.7	6754.48
209.1	5931.5
216.7	5492.89
224.7	5005.34
232.9	4463.26
241.4	4102.66
250.3	3415.91
259.5	3192.58
269.0	2623.91
278.8	2321.15
289.0	2190.26
299.6	1809.74
310.6	1494.35
322.0	1256.12
333.8	1194.4
346.0	1003.25
358.7	838.367
371.8	720.34
385.4	603.203
399.5	458.194
414.2	444.368
429.4	329.924
445.1	338.165
461.4	238.16
478.3	187.359
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.2247
High Voltage	9834.41
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	52.8859
Mean(nm)	57.0634
Geo. Mean(nm)	52.6164
Mode(nm)	53.2798
Geo. Std. Dev.	1.49528
Total Concentration(#/cm)	2.77827e+007
Comment	
